Direct line in protection connector

Detalles del producto

This 30 mA Personal Residual Current Device (PRCD) protects you against electrical accidents on board, is designed for harsh conditions on board, is sealed water-tight, and is connected "flying" between a live power outlet and the power cord of an electrical load. The safety switch only monitors the loads that are connected to this socket. Maximum load capacity 16 amps or 3600 watts. Delivered pre-assembled with Schuko plug and coupling, total length 3 meters.

Details

  • 230 V AC, max. 16 A or max. 3600 W
  • Switch-off: double-pole (L + N)
  • Trip current: 30 mA
  • Tripping time: <30 mS
  • Simple 2-button operation: green activation button (RESET) and blue test button (TEST)
  • Function display above the RESET button
  • Circuit breaker with control buttons and function display IP55 (jet-proof)
  • Schuko plug/coupling IP44 splash-proof (when plugged in)
  • Rubber cable 3 x 2.5 mm² (H07RN-F)


Note

  • If required, the Schuko components can be replaced with CEE plugs and CEE couplings.
    However, this should only be done by an electrician.
  • This item only monitors the electrical loads that are connected to it, not those in the preceding system.
  • This residual current circuit breaker should be regularly checked for proper function after each connection to a power outlet and also after prolonged use on this outlet.


Operation and function test

  1. Plug the Schuko plug into a live socket, e.g. at the dock, in a hall, etc.
  2. Press the green "RESET" button.
    The small display above the "RESET" button turns red, signaling that the 230 V AC is available at the outlet and that the FI is working.
  3. Pull the Schuko plug out of the socket.
    The red indicator turns off.
  4. Repeat step 1 and 2.
    The red operating display signals again that the FI is working.
  5. Now press the blue "TEST" button.
    The red operation display has to turn off immediately, which means that the 230 V at the outlet is switched off at the same time.
  6. Following this test, press the green "RESET" button again.
    The red operating display lights up again. Now the proper function is tested and a fault-current protected power supply of the connected loads is guaranteed.

Esto es lo que otros clientes de SVB opinan

Evaluaciones 100% auténticas
Thomas H.
Bandera nacional de Austria Compra verificada
producto como se esperaba.
Usuario anónimo
El dispositivo da una impresión sólida y estable. Muy práctico e importante para todas las embarcaciones que no tienen una conexión a tierra instalada de forma permanente con un disyuntor FI, pero que aún así no quieren prescindir de la toma de tierra.
Andreas P.
Bandera nacional de Alemania Compra verificada
Manejo, como de costumbre con SVB super

Evaluar producto

¿Cómo calificaría el producto?
Decepcionante
No cumple en absoluto mis expectativas
Malo
Sólo cumple algunas expectativas
OK
Cumple mis expectativas básicas
Bueno
Cumple la mayoría de mis expectativas
Excelente
Cumple y supera totalmente mis expectativas
Haga clic en las estrellas para calificar

Clientes preguntan a clientes

Haga sus preguntas a otros clientes de SVB que ya han comprado este producto y obtenga su opinión.

Su pregunta será automáticamente enviada a otros clientes de SVB y publicada en la página del producto. Por favor no realice preguntas que sólo el equipo de SVB puede responder, como el estado de un pedido o la disponibilidad de un producto. Para preguntas que se refieren a un pedido, por favor contacte a nuestro equipo SVB por email info@svb-marine.es o por teléfono al: 960 13 06 40 .

Aún no existen preguntas sobre este producto. ¡Sea el primero en realizar una pregunta!